Product Information

  • Model:YJ-F6
  • Certification:CE
  • Dimension:12.1 inches LCD
  • Packaging Details:Standard Package
  • Brand Name:FORERMED
  • Place of Origin:China
  • Warranty:1 year
  • Screen:12.1 Inches LCD
  • USB Mouse/Keyboard Control:Optional
  • Waveforms:Support Display 9-12 Waveforms
  • 7 Channel ECG Waveform Display:Support
  • Built-in High-Speed 50mm Thermal Printe:Brand,Seiko, Japan
  • Support Wired/Wireless Connection:Support
  • Real-Time S-T Segment Analysis:Support
  • Drug Calculation and Titration Table:Support
  • Multi-Language Display:Support
  • Online Software Upgrading by Net/USB:Support

Description

 YJ-F6 Multi-parameter Patient Monitor (12.1 inches)
Technical Data Sheet - Release V1.0





The  YJ-F6 patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments. Pacemaker detection and Arrhythmia analysis..
 
An optional USB Mouse/Keyboard control eases navigation and data entry.
Humane fashion design and handle of humanized integration design, easy to carry.
 
Designed without fan, characterized with no noise and lower consumption.


 
 
CE/ISO/RoHS/CFDA
 
 
Features


Core
  1. Newly advanced A9 main board with Linux OS, calculating speed is 4 times faster than traditional products

  1. Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events review
 
Body
  1. 12.1 inch high-brightness TFT LED
  2. Support display 9~12 waveforms
  3. Support 7 channel ECG waveform display
  4. Optional touch screen
 
Printer
  1. Built-in high-speed 50mm thermal printer
 (Brand: SEIKO, Japan)
 
Central System
  1. Support wired/wireless connection to the central monitoring station.
 
Alarm
  1. Three-level acousto-optic alarm
  2. Sensor-off alarm
  3. Paper out alarm
  4. Support alarm review
  5. Support alarm pause




ECG Full LeadBig Font DisplayStandard Display



OxyCRGTrend TableNIBP Review
OS
  1. Support operation with mouse and computer keyboard (option)

  1. Multi-display mode to meet different clinical requirement, including standard, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface.

  1. NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
  2. Generate ID automatically when register a new patient

  1. Support medical history search by patient ID, name and mobile number

  1. 18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection

  1. Drug calculation and titration table 

  1. Support multi-language display
  2. Support online software upgrading by net/USB
Interface




Transducer socket
  1. ECG
  2. SPO2
  3. NIBP  
  4. IBP 1 / IBP 2
  5. TEMP 1 / TEMP 2 (Mainstream EtCO2)
 
LAN / Central monitor system interface
  1. The LAN port is for connecting the monitor to a central monitor system network.
 
Input device interface
  1. Knob (Standard)
  2. USB interface (optional)
  3. Touch screen (optional)

  1. This optional interface provides an USB ports to enable the monitor to be connected to off-the-shelf input devices:
  2. Mouse: any specified trackball or USB mouse may be used for navigation and data entry.
  3. Computer keyboard: an USB computer keyboard can be used for data entry instead of the on-screen pop-up keyboard.
[Remark: user has to restart the machine after plug and unplug the mouse / computer keyboard.]
  1. Knob (Standard)
 
Service Features
  1. The Support Tool helps technical personnel to
-  carry out configuration, upgrades and troubleshooting on an individual monitor.
  1. back up the monitor settings.

  1. The Service Mode is password-protected and ensures that only trained staff can access service tests and tasks. It includes Skin Type, Brightness Setting, Clear Data and NIBP Calibration.
  2. The Support Tool uses the USB interface of the monitor for software upgrading.
Related Product


  1. IBP accessories

  1. Respironics EtCO2 module

  1. Nellcor SpO2 module

  1. Masimo Spo2 module
 
 


Performance Specifications


 
Dimension and Weight
  • Dimension: 375mm*330mm*180mm
  • Weight: 3.4kg (excluding accessories)
 
Power Supply
  • Voltage: AC100~240V, 50/60HZ,
  • Power≤60W
 
Display
  • 12.1" color TFT LED
  • Resolution: 800*600 pixels
 
Battery
  • Type: Rechargeable lithium battery:
     12V/2200mAh
  • Charge Cycle: ≥500 times
  • Working time: 2 hours
 
Recorder (Option)
  • Method: Thermal printer
  • Paper width: 50 mm (1.97 in)
  • Printing speed: 12.5/ 25/ 50 mm/s
  • Trace: Max. 3 tracks
  • Recording way: Real-time Recording, Review Printing,  
    Periodic Recording, Alarm Recording
 
Alarm
  • Level: Low, medium and high
  • Indication: Auditory and visual
  • Alarm volume adjustable
  • Alarm pause time: 1min, 2min
  • Parameter alarm type: Latch/ Unlatch
 
Input Device
  • Touch screen (option)
  • Knob (Standard)
  • Keypad input (Standard)
  • Mouse/ Keyboard input (option)
 
System Output & Extensible
Interface
  • Ethernet Network: 1 standard RJ45 socket
 
Safety
  • IEC60601-1 Approved, CE marking according to MDD93/42/EEC
  • With reference to RoHS Directive 2011/65/EU recasting
 
 
 
 
Trend & Reviewing
  • Trend: 2160 hours
  • ARR events: 128 groups of ARR events and associated waveform
  • NIBP measurement reviewing: 2000 groups
  • Waveform review: 2 hours
Alarm event: 2000 groups of parameter alarms events and associated parameter
 
ECG
  • Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
  • Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
  • Sweep speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50 mm/s
  • ECG signal range:  ±12 mV (Gain × 0.25) Auto
  • ECG signal range:  ±6 mV
  • Accuracy: ±1bpm/ ±1%, whichever is greater
  • Resolution: 1 bpm
  • Leakage Current < 10 μA
  • Baseline Recovery:
 < 5 s after defibrillation (MOR or Surgery mode)
  • Bandwidth: Surgery 1 ~ 20 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 130 Hz
  • Indication of Electrode Separation: Every electrode (exclusive of RL)
 
Heart Rate
  • Measure range:
Adult: 0bpm; 15 ~ 300 bpm
Neo/Ped: 0bpm; 15 ~ 350 bpm
  • Resolution: 1 bpm
  • Accuracy: ± 1% or ± 1bpm, whichever is greater
 
ST Measurement
  • Range: -2.0 ~ +2.0 mV
  • Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
  • Other range: unspecified
  • Resolution: 0.01mV
 
Respiration
  • Method: Impedance between RA-LL, RA-LA
  • Gain: ×0.25, ×0.50, ×1, ×2
  • Respiration Rate: Adult: 0 ~ 120 BrPM;
          Neonatal / Pediatric: 0 ~ 150 BrPM
  • Resolution: 1 BrPM
  • Accuracy: ±2 bpm or ±2%, whichever is greater
  • Apnea Alarm: 10 ~ 40 s
 
 
SpO2 (Analog Technic)
  • Measurement Range: 0 ~ 100 %
  • Resolution: 1 %
  • Accuracy: 70% ~ 100%: ±2 %  
         40% ~ 69%, ±3 %;
         <39%, unspecified;
 Pulse Rate
  • Measuring and Alarm Range: 20~300bpm
  • Accuracy: ±3bpm
  • Resolution: 1bpm
 
Nellcor-SpO2 (Option)
  • Measurement Range: 0 ~ 100 %
  • Resolution: 1 %
  • Accuracy:   70% ~ 100%, ±2 % (adult)
             70% ~ 100%, ±3 % (Neonate)
             70% ~ 100%, ±2 % (Low Perfusion)
             0% ~ 69%, unspecified
 
Pulse Rate
  • Measurement range: 20 ~ 300 bpm
  • Resolution: 1bpm
  • Accuracy:
±3 bpm (20 ~ 250 bpm)
Unspecified (251~300 bpm)
 
Masimo-SpO2 (Option)
  • - Measurement Range: 0 ~ 100 %
  • - Resolution: 1 %
  • Accuracy:  
70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
70% ~ 100%, ±3 % (neonate, non-motion conditions)
70% ~ 100%, ±3 % (motion conditions)
0% ~ 69% unspecified
 
Pulse Rate
  • Measurement range: 25 ~ 240 bpm
  • Resolution: 1bpm
  • Accuracy: ±3 bpm (non-motion condition)
 
Temperature
  • Technique: Thermistor probe (2.25K/10K)
  • Channel: Dual-Channel, provide T1; T2; ΔT
  • Measuring and Alarm Range:
0.0 ºC~ 50 ºC (32ºF~ 122ºF)
  • Unit: Celsius (ºC), Fahrenheit ( ºF)
  • Resolution: 0.1ºCor 1ºF
  • Accuracy: ±0.1ºC(exclusive probe error)


Performance Specifications


 
NIBP
  • Method: Oscillometric
  • Measure mode: Manual, Auto, STAT
  • STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
  • Measure and Alarm Range:
Adult:       SYS:  40 ~ 280 mmHg
           DIA:  10 ~ 220 mmHg     
           MEAN:  20 ~ 240 mmHg
Pediatric: SYS:  40 ~ 220 mmHg
DIA:  10 ~ 160 mmHg     
MEAN:  20 ~ 170 mmHg
Neonate:   SYS:  40 ~ 135 mmHg
DIA:  10 ~ 100 mmHg     
MEAN:  20 ~ 110 mmHg
  • Static pressure accuracy: ±3mmHg
  • Resolution: 1mmHg
  • Accuracy: Maximum Mean error ±5mmHg           
         Maximum Standard deviation 8mmHg
  • Over pressure Protection: Dual protection via software & hardware
 
 
 
 
 
EtCO2 (Mainstream) (Option)
  • Measure method:  Non-dispersive infrared (NDIR)
  • Measure Range:  0 ~19.7% (0 ~ 150 mmHg)
                 0 ~ 20 kPa
  • Resolution: 0.1 mmHg
  • CO2 Accuracy:  
0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 25ºC)
  • Respiratory Rate:  Range: 3 ~150 BrPM
                Accuracy: ±1 bpm
 
IBP (Option)
  • Max Channel: 2
  • Measurement way: Thermal resistance way
  • Press Sensor:  Sensitivity   5 uV/V/mmHg, ±2%
              Impedance   300 to 3000Ω
  • Resolution: 1 mmHg
  • Unit: mmKg, kPa
   